EXERCISE 01
Close the exhaust
Reduce the exhaust opening, then close it. Compare the modelled inflow and smoke movement.
Discuss: Why does a powered fan not guarantee sustained flow through the building?
PRACTISE WITH PURPOSE
A practical guide to setting up a session, understanding the model and turning observations into useful discussion.
01 / SET UP
Keep plans appropriate for the audience. Floor plans and scenarios stay in your browser unless you export and share them. An exported scenario includes its uploaded plan image.
02 / EXPLORE TOGETHER
Begin with a smoke-filled layout, an open entrance and an exhaust path. Ask the crew to predict the effect before making each change. These exercises explore model behaviour, not operational ventilation tactics.
EXERCISE 01
Reduce the exhaust opening, then close it. Compare the modelled inflow and smoke movement.
Discuss: Why does a powered fan not guarantee sustained flow through the building?
EXERCISE 02
Close the door to a smoke-filled bedroom. Compare it with a room that still connects to the flow path.
Discuss: Which rooms remain connected? What information is missing from this simplified view?
EXERCISE 03
Open another exterior door or window. Watch how the model divides flow between available routes.
Discuss: Which path has changed, and which compartments lie along it?
EXERCISE 04
Toggle a fire source in one room. Compare ongoing smoke production with clearing smoke after that source is switched off.
Discuss: How could supplying oxygen change a real fire? The model does not calculate that feedback.
Finish with the limits. Clearer shading or a lower smoke percentage is not evidence of safe entry, breathable air or successful fire control. Refer operational decisions back to current CFA procedures, incident conditions and command.
03 / UNDERSTAND THE MODEL
The lab represents a building as a two-dimensional plan with one uniformly mixed smoke concentration per room. Room area and ceiling height determine compartment volume. Openings connect rooms to each other or to outdoors. A steady pressure calculation estimates the flow through those connections.
Here, A is the effective opening area, ΔP is the pressure difference, and ρ is the assumed air density. The opening discharge coefficient is 0.7 and density is 1.2 kg/m³. These are model inputs, not measurements of your building.
This is not computational fluid dynamics (CFD) or a validated fire model. It does not calculate thermal layers, buoyancy, turbulent jets, recirculation, wind, leakage, oxygen concentration, combustion, fire growth, temperatures or heat exposure. Closed openings are treated as sealed. It does not predict flashover, backdraught, tenability, safe entry, firefighter survival or ventilation clearance times.
Real fire smoke can move without a fan because of heat, buoyancy and wind. These effects are outside this model. The coloured arrows indicate the modelled flow direction; they do not establish that the air is fresh or safe to breathe.
Active fire is a critical limitation. Ventilation can supply oxygen and increase fire growth. The fire marker is a smoke source only and does not reproduce this response. Increasing fan speed must never be interpreted as automatically making conditions safer.
04 / EQUIPMENT REFERENCES
The presets identify particular manufacturer publications. Confirm the model and generation on the brigade's actual equipment before using the specifications for familiarisation.
| Reference preset | Published battery airflow | Published test arrangement |
|---|---|---|
| EX50Li Gen II, 40 VNot the newer G3 or 18 V versions | 17,194 m³/h10,120 cfm; approximately 4.776 m³/s | 3,045 rpm 4.3 m setback; 9° tilt |
| EX150LiBattery operation reference | 21,029 m³/h12,377 cfm; approximately 5.841 m³/s | 3,600 rpm 4.9 m setback; 11° tilt |
AMCA reference flow is not guaranteed building flow. The published rating is airflow entering a test chamber in a specified arrangement, including entrained air. It is not simply flow at the impeller outlet and does not establish performance in an arbitrary floor plan.
The lab's percentage control is an approximate model setting. It does not reproduce an actual control-knob position or certified RPM. The simulator does not model vertical tilt; the test angles above are source context only. A manufacturer pressure curve has not been incorporated.
05 / PANEL FAMILIARISATION
Open Fire indicator panels to access the available simulators. Ask members to identify the panel, interpret indications and explain the effect of a control before using it.
Simulator behaviour and generic illustrations do not establish the correct action for every installed system. Use the applicable manufacturer manual, site information and current CFA procedures. Verify panel-specific differences during supervised practical familiarisation.
06 / FURTHER READING
These sources explain the equipment references and research context. They do not validate this simulator or make it an official CFA training package.